b'APPENDIX BEVALUATION STATEMENTS B1 Evaluation methods 1.Fire Safety ProvisionsA5G3(1)(d)&(e). Reports from Accredited Testing Laboratories and a professional engineer. 2.Structural ProvisionsA5G3(1)(e). Reports from a professional engineer. 3.Thermal ProvisionsA5G3(1)(d)&(e). Reports from Accredited Testing Laboratories and a professional engineer.4.Weatherproofing ProvisionsA5G3(1)(e). Reports a professional engineer. B2 Reports 1.Summermore Pty Ltd, Certificate No. 23-28904-T1, Generic Compliance Certificate for building design or specification, dated 12/09/2023. This report provides compliance for the AS 1562.1, F3D5, H1D7 & H2D6 based on the span tables nominated within. 2.Summermore Pty Ltd, Certificate No. 23-28904-T2, Generic Compliance Certificate for building design or specification, dated 12/10/2023 This report provides compliance for the AS 1562.1, F3D5, H1D7 & H2D6 based on the span tables nominated within. 3.BRANZ, IANZ Accreditation No.37, Report Number FI6323-01-2, AS ISO 9705 (R2016) & ISO 9705:1993 FIRE TEST OF PHENOLIC COMPOSITE, INSULATED BUILDING PANEL, dated 25/05/2023. This report contributes compliance to C2D11 for the TPC Core.4.BRANZ, IANZ Accreditation No.37, Report Number FAR 2849, ASSESSMENT OF THE PERFORMANCE OF METAL CLAD EXPANDED POLYSTYRENE SANDWICH PANELS IN THE AS ISO 9705:2003 (R2016) ROOM FIRE TEST, dated 23/2/2021. This report contributes compliance to C2D11 for the EPS-FR Core. 5.AWTA, NATA Accreditation No.1356, Report Number 18-006076, Testing to AS 1530.3 1999, dated 25/5/2023, This report contributes compliance to C2D11 for the EPS-FR Core.6.AWTA, NATA Accreditation No.1356, Report Number 23-000591, Testing to AS 1530.3 1999, dated 20/2/2023, This report contributes compliance to C2D11 for the TPC Core. 7.BRANZ, IANZ Accreditation No.37, Report Number DI17595-01, THERMAL TESTING OF EPS-FR 50MM, dated 5/4/2023. This report contributes compliance towards J4D6 & H6D2 for the EPS-FR Core. 8.BRANZ, IANZ Accreditation No.37, Report Number DI17595-02, THERMAL TESTING OF EPS-FR 200MM, dated 5/5/2023. This report contributes compliance towards J4D6 & H6D2 for the EPS-FR Core. 9.BRANZ, IANZ Accreditation No.37, Report Number DI17801-01, THERMAL TESTING OF TPC 50MM. dated 27/6/2023. This report contributes compliance towards J4D6 & H6D2 for the TPC Core. 10.BRANZ, IANZ Accreditation No.37, Report Number DI17801-02, THERMAL TESTING OF TPC 200MM. dated 7/7/2023. This report contributes compliance towards J4D6 & H6D2 for the TPC Core. 11.James M Fricker Pty Ltd, Report i518c, Calculation No. 548w03, DECLARED R OF FLAT SANDWICH PANELS THERMAL PERFORMANCE CALCULATIONS TO AS/NZS 4859 Parts 1 & 2:2018, dated 2/6/2023. This report contributes to the thermal compliance of J4D6 & H6D2. 12.James M Fricker Pty Ltd, Report i518c, Calculation No. 548w03b, DECLARED R OF FLAT SANDWICH PANELS THERMAL PERFORMANCE CALCULATIONS TO AS/NZS 4859 Parts 1 & 2:2018, dated 2/6/2023. This report contributes to the thermal compliance of J4D6 & H6D2. 13.CSIRO Pty Ltd, NATA Accreditation No.165, Report Number FSZ 2373, Bushfire test on an external wall system, dated 09/06/2023 provides compliance for G5D3 & H7D4 for the TPC Core. 14.BRANZ, Report No. FC10893-001, ASSESSMENT OF DELTA PANELS PTY LTD DELTACOOL WALL AND DELTATRIM AND DELTAORB ROOFING SYSTEMS FOR COMPLIANCE WITH BAL-29 AND BAL-40 RATINGS OF AS 3959-2009, dated 24/10/2018 provides compliance for G5D3 & H7D4 for the EPS-FR Core. The Certificate Holder has chosen not to make the above evidence of compliance publicly available, due to the documents being considered commercial in confidence.Certificate number: CM40365-I01-R00This certificate is only valid when reproduced in its entirety.Page 9 of 9'