b'DeltaTrimCorro-TPCSPECIFICATIONSDetail B Detail AAcoustic PerformanceDeltaTrimCorro-TPC Acoustic Testing has been performed in compliance with the requirements of AS 1191-2002 Acoustics -MethodforLaboratoryMeasurementofAirborneSound Early Fire Hazard Properties AS 1530.3:1999 Insulation of Building Elements.TheproceduresspecifiedbyAS/NZSISO717.1:2024were AWTA Test Report 23-000591 20-02-2023 used to calculate the Sound Transmission Class (STC) and the ExternalWeighted Sound Reduction Index Rw = 25 dB.Index Test Range Top SkinIgnitability 0-20 0 Trafficable StatusSpread of Flame 0-10 0 DeltaTrimCorro-TPC is classified as trafficable when used for Heat Evolved 0-10 0 maintenance purposes. The following recommendations should Smoke Developed 0-10 1 be observed at all times. Wear flat, rubber soled shoes Walk over the roof supporting beamsDeltaTrimCorro-TPC Acoustic ValuesSpread your weight over as many roof crests as possibleCrawl boards should be used when accessing areas not 75mm 150mmsupported by a structure100 15.41 15.00 DeltaTrimCorro-TPC Fixing Details160 16.40 15.09 Crest fixing only. One fixing every second crest200 18.81 17.70 Panel 250 19.70 18.51 ThicknessFixing into Steel Fixing into Timber(mm)315 21.39 19.40 75 Tek 14 x 175 Hex Head Screw T17 14 x 175 Hex Head Screw400 22.31 19.69 100 Tek 14 x 200 Hex Head Screw T17 14 x 150 Hex Head Screw630 23.40 19.10 125 Tek 14 x 230 Hex Head Screw T17 14 x 230 Hex Head ScrewFrequency 800 23.69 17.31 150 Tek 14 x 260 Hex Head Screw T17 14 x 265 Hex Head Screw1000 25.61 18.291250 21.01 30.10 175 Tek 14 x 300 Hex Head Screw T17 14 x 300 Hex Head Screw1600 20.00 36.19 200 Tek 14 x 300 Hex Head Screw T17 14 x 300 Hex Head Screw2000 34.79 37.30 Use Cyclone Plate and Neo Washer on each fixing.2500 41.70 37.09 Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.3150 44.10 35.69 As at the stated Version Date all of the information contained in this document is correct. Please check on our WebPage 5000 44.61 39.90 to ensure that youre referencing the current version. STC 24.00 23.00RW 25.00 24.00Delta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2024-11-24W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'