b'- M W SPECIFICATIONSDeltaOrb-MW is an Insulated Roof Panel System, comprising of two pre-painted, roll-formed steel skins, with a roll-formed steel skins bonded to a non-combustible mineral wool core.CodeMark Australia Certificate CM40345 DeltaFireX Car PortSystemincorporatingDeltaOrb-MWpanelscertifies compliance with the stated performance provisions of the NCC 2022Amendment 2 . Please refer to the certificate, as displayed on our web page, for the exact details of the compliance.CodeMark Australia Certificate CM40346 Class 10a Awning andPatioRoofSystemincorporatingDeltaOrb-MWand DeltaOrb-EPS panels certifies compliance with the stated performance provisions of the NCC 2022Amendment 2 .Detail A Detail BPlease refer to the certificate, as displayed on our web page, for the exact details of the compliance. Top Skin 0.42mm / G550 AZ150Steel Skin Details Bottom Skin 0.55mm / G300 Z275Fire Test Certificate - AS ISO 9705 Max. Skin Temperature 78oC Dry HeatGroup 1 Classification in accordance with NCC 2022 Volume One Amendment 2 Clause C2D11 & Clause S7C4 determinedCore Material Details Mineral Woolin accordance with AS 5637.1:2015 as per Jensen Hughes test report 252674 issued 28 November 2025 & Spectra FireThermal Conductivity 0.0365 W/mK @23.0oCEngineers report 25367 issued 25 November 2025 AS 1366.2/ASTM C 518Core Density 100kg/m 3Combustibility Test AS 1530.1-1994 75mm Panel 18.50CSIRO Report no. FNC12604 dated 8/7/2020 tested five (5)0.6mm Skin Weight (kg/ 100mm Panel 21.00samples of the Delta Panels supplied mineral wool sample andm 2 ) 125mm Panel 23.50certified that the material is NOT deemed combustible according to the criteria specified in clause 3.4 of AS 1530.1-1994. 150mm Panel 26.00Thickness Winter (15o ) Summer (30o )Sotera - FireX Car Port System 2 75mm Panel 2.50 2.35The Sotera report A21007 J005 - DeltaFireX Car Port System FERR Value (m .K/W) dw rev 1-4 (NOTE REV 1-4) confirms that the FireX Car PortAS/NZS 4859 Parts 1 &100mm Panel 3.20 3.00System meets the performance requirements of H3P1 Volume2:2018 125mm Panel 3.90 3.702, NCC 2022 Amendment 2 when installed in accordance with150mm Panel 4.60 4.35the DeltaFireXRoof Brochure version V25.12.04 and section 4.4 of their report as a Class 10a structure (car port) attached orCertificate of Conformity CM40435 & CM40436adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e.) less than 900 mm from the site boundary) Sheet Coverage 1000mmSotera - Delta MW and EPS-FR Awning & PatioLength (mm) Cut to Length Min of 1800mmRoof System Length Tolerance (mm) 5mm+/-TheSoterareportA21007J004-DeltaMWandEPS-FRThickness (mm) 75, 100, 125, 150Awning and Patio Roof System FER dw rev 1-4, confirms that the Mineral Wool & EPS-FR Awning & Patio Roof System meetsBuilding Classes 1-9 - 5the performance requirements of H2P1 Volume 2, NCC 2022Minimum Roof PitchAmendment 2 when installed in accordance with the DeltaBuilding Class 10- 3Mineral Wool Panels Brochure version V25.12.04 and section 4.4 of their report as a Class 10a structure (car port) attached orSurface deformations can be adjacent to a Class 1a building positioned directly adjacent toFlatness 0.40mmapparent to the naked eye when the site boundary (i.e.) less than 900 mm from the site boundary) Standards 0.60mm observed in certain lighting conditionsDelta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 07 3271 2170 Version Date: 2025-12-04W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 02 4611 7712'