b'Certificate number: CM40330 Rev1 Certification Body: THIS IS TO CERTIFY THAT DeltaTrimTMDualCoreTM & DeltaOrbTMDualCoreTM Panels ABN: 81 663 250 815 JAS-ANZ AccreditationType and/or use of product:Description of product:No. Z4450210AKRoof panel for Awnings & Patios which are situated within 900mm of a site boundary and attachedTwo pre-painted, roll-formed steel DeltaTrim TMor DeltaOrb TMskins bonded to a Mineral Wool PO Box 273, Palmwoods Qld 4555or adjacent to a Class 1a building. (minimum coverage 900mm) and fire retardant SL Grade Expanded Polystyrene core (EPS). Refer A2 Australiafor more information.P: +61 7 5445 2199 www.cmicert.com.au COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S)BCA 2019 (Amdt. 1) office@cmicert.com.au Volume OneVolume TwoCertificate Holder:Performance Requirement(s):Not ApplicableP2.3.1(a)Spread of fire Deemed-to-Satisfy Provision(s):Not Applicable Not ApplicableState or territory variation(s): Not Applicable Not ApplicableDelta Panels Pty Ltd ABN: 11 147 861 292SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B 731 Boundary Road,Limitations and conditions:Building classification/s: Richlands, QLD, 4077 1.Compliance with P2.3.1(a) is subject to site specific performance solution to the satisfaction of the Appropriate Authority as described by the NCC.Ph: 07 3271 21702.Any Proposed Performance Solution must be predicated on the following factors and characteristics:Class 10awww.deltapanels.com.aua.Two or more sides (making up at least one third of the awning or patio perimeter) shall be open; that is the roof covering shall be more than 500 mm from another building or allotment boundary on at least two sides without enclosing these sides with a wall, privacy screen or the like within 500mm of the edge of the roof covering. A boundary along a road or public space such as parklands, lakes, rivers and the like (where the construction of buildings is unlikely) may be considered open regardless of proximity to the boundary subject to no vertical obstruction (wall, privacy screen or the like) within 500 mm of the edge of the roof covering.b.The awning or patio structure shall not provide direct vertical support to any part of the adjacent Class 1 building.c.The portion of the awning system which is located within 900 mm of a site boundary shall consist solely of non-combustible components (subject to (d)) including:i.Mineral woolii.Pre-finished steel sheeting with combustible surface finish not exceeding 1 mm thickness and with a spread of flame index no greater than 0 in accordance with NCC Clause 3.7.1.1(e).iii.Steel fixtures, gutters and the likeiv. Steel columns, beams, purlins and the like v. Metallic flashing d.As the DeltaDualCore panel constitutes a bonded laminate, the following restrictions shall apply to the portion of the panel that is within 900mm of the site boundary:Date of issue: 17/01/2023 Richard Donarski - CMIDon GrehanUnrestricted Building CertifierDate of expiry: 28/09/2024Certificate number: CM40330 Rev1This certificate is only valid when reproduced in its entirety.Page 1 of 4'