b'Certificate number: CM40346 Rev2 Certification Body: THIS IS TO CERTIFY THAT Delta MW and EPS Panel Class 10a Awning and Patio Roof System ABN: 81 663 250 815 JAS-ANZ AccreditationType and/or use of product:Description of product:No. Z4450210AKTo be used for Class 10a Awning and Patio structures that are attached or adjacent to a Class 1aDelta MW and EPS Panel Class 10a Awning and Patio Roof System incorporates DeltaTrim-MW or PO Box 273,building that run parallel with a side boundary and is within 900mm of that side boundary.DeltaOrb-MW Panels (within 900mm of the boundary) and DeltaOrb EPS-FR or DeltaTrim EPS-FR Palmwoods Qld 4555panels of the same thickness and profile for the remaining section of the structure. Refer A2. Australia P: +61 7 5445 2199 www.cmicert.com.au COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S)BCA 2022 office@cmicert.com.au Volume OneVolume Two Performance Requirement(s):Not ApplicableH3P1(1)Contributes to the Spread of fire subject to Limitation and Certificate Holder:Condition 1 Deemed-to-Satisfy Provision(s):Not ApplicableNot ApplicableDelta Panels Pty LtdState or territory variation(s): Not ApplicableNot Applicable ABN: 11 147 861 292SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B 731 Boundary Road, Richlands, QLD, 4077Limitations and conditions:Building classification/s: Australia 1.Compliance with H3P1(1) is subject to site specific performance solution to the satisfaction of the Appropriate Authority as described by the NCC. Class 10aPh: 07 3271 21702.The Delta MW and EPS Panel Class 10a Awning and Patio Roof System is only to be used as a Class 10a Awning and Patio structure.www.deltapanels.com.au3.In the absence of a site-specific performance solution, this system must not be used to facilitate the exemptions for a carport specified in Part 9.2.8 Open carports of the ABCB Housing Provisions.4.Construction shall be in strict accordance with A5 of this Certificate of Conformity.5.Compliance with H3P1(1) is dependent on the system as specified in A3. Any deviation from the described system does not form part of this Certificate of Conformity.6.The structural support members are designed and engineered separately as per project requirements by building designers and engineers. 7.The use of the certified product/system is subject to these Limitations and Conditions and must be read in conjunction with the Scope of Certification below.Date of issue: 05/08/2024 Richard Donarski - CMIDon GrehanUnrestricted Building CertifierDate of expiry: 11/05/2025Certificate number: CM40346-I01-R02This certificate is only valid when reproduced in its entirety.Page 1 of 6'