b'DeltaOrb - DCSPECIFICATIONSSteel Skin Details Top Skin0.42mm / G550 AZ150ColorBondBottom Skin0.55mm / G300 Z275Max. Skin78 o C Dry HeatTemperatureDetail A Core Material Details Minimum of 900mm Mineral Wool with the balance in EPS-FRDetail B Thermal Conductivity Minimum 0.0363 W/mK @ 23.0 o CAS 1366.2/ASTM C 518Average density for a 6.0 metre panel is Core Density 30.8kg/m 3CodeMark Certification of* CodeMark Australia Certificate CM40330ConformityDeltaOrb-DCis a CodeMark Approved Patented Insulated50mm Panel 13.1Roofing Systemfor boundary applications that complies75mm Panel 13.9with the non-combustibility requirements of Part 3.7 of thePanel Weight (kg/m 2 )National Construction Code (NCC) 2019 Volume Two.(based on average weight100mm Panel 14.7Itcomprisestwopre-painted,roll-formedsteelskins,over a 6 metre panel) 125mm Panel 16.7encapsulating a combination of Expanded Polystyrene150mm Panel 18.7FireRetardantGrade(EPS-FR)InsulationwithMineral Wool (MW) Insulation. The Mineral Wool Core is positioned50mm Panel 1.3at the end of the panel when constructing a Class 1075mm Panel 2.0structure within 900mm of the boundary line.R Value - Minimum 100mm Panel 2.7Early Fire Hazard Properties AS 1530.3:1999 125mm Panel 3.4AWTA Test Report 18-006076 14-11-2018 150mm Panel 4.1Index Test Range External Top SkinIgnitability 0-20 0 Sheet Coverage 1000mmSpread of Flame 0-10 0 Length (mm) Cut to Length Min of 1800mmHeat Evolved 0-10 0 Length Tolerance (mm) 5mm+/-Smoke Developed 0-10 2Thickness (mm) 50, 75, 100, 125, 150Minimum Roof Pitch 3 for Class 10 BuildingsSurface deformations can be Flatness 0.40mmapparent to the naked eye Standards 0.60mm when observed in certain lighting conditionsInnovation Patent No.2021104435Delta Panels Pty Ltd - ABN: 11 147 861 292P: +61 07 3271 2170 Head Office: 731 Boundary Road, Richlands, Qld 4077E: info@deltapanels.comSydney Depot: 11 Old Northern Road, Narellen NSW 2567 Version Date: 2024-02-06W: www.deltapanels.com'