b'DeltaDualCore Panel Awning Systems Sandwich Panel with Expanded Polystyrene (EPS) CoreTestReportTest SpecimenRelevant Performance 3.AS1530.3:1999AWTA Test No.Pre-painted steelIndices: 19-003621 (referskins (DeltaOrb) Ignitability: 0 to Section D.1)bonded to an EPS core with fireSpread of Flame: 0 retardant. Heat Evolved: 0 Smoke Developed: 2 4.AS1530.3:1999AWTA Test No.Pre-painted steelIndices: 19-003623 (referskins (DeltaTrim) Ignitability: 0 to Section D.2)bonded to an EPS core with fireSpread of Flame: 0 retardant.Heat Evolved: 0 Smoke Developed: 2 5.AS3959:2009Branz FireDeltaTrim andDeltaOrb - BAL40 AssessmentDeltaOrb steel DeltaTrim - BAL40 Report FC10893- facings (0.40 mm or 001 (refer to0.60 mm) with EPS Appendix F)core with thickness up to 150 mm thick. Coated Steel Facings TestReport Test SpecimenRelevant Performance 6.AS1530.3:1999CSIRO ReportBlueScopeIndices: No. FNE11602ZINCALUME Steel Ignitability: 0 (refer to Section(0.5 mm nominal D.3)thickness)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 7.AS1530.3:1999CSIRO ReportBlueScopeIndices: No. FNE11604COLORBOND steel Ignitability: 0 (refer to Section(0.8 mm nominal D.4)thickness)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 8.AS1530.3:1999CSIRO ReportBluescopeIndices: No. FNE11603COLORBOND Ignitability: 0 (refer to SectionPermagard Steel (0.7 D.5)mm nominalSpread of Flame: 0 thickness)Heat Evolved: 0 Smoke Developed: 1 9.AS1530.3:1999AWTA Test No.MagnaFlow CoatedIndices: 19-002186 (referSteel Panel (nominal Ignitability: 0 to Section D.6)mass per unit density 7850 kg/m 3 )Spread of Flame: 0 Revision 1-1119'