b'DeltaDualCore Panel Awning Systems Appendix BFDS Assessment B.1Introduction An FDS analysis is undertaken to assess the combined heat transfer to the site boundary for the DeltaDualCore system when compared to the DtS base case. B.2Model Geometry The model geometries for each of the three FDS models use are described in Figure 5-3, Figure 5-4 and Figure 5-5 and include: 1.Model 1: DtS base case. 2.Model 2: DeltaDualCore awning with equivalent dimensions to Model 1 (performance solution case). 3.Model 3: Sensitivity case where the width of the awning in Model 2 is increased by 100%.Site boundary A Upper surface of roof is Ba burner with constant HRRPUA of 332 kW/m 210MW Peak HRR fire 4 m4 m 6 m 2.95 m 2.7 m C D6 m 5 m FRONT VIEWSIDE VIEWFigure 5-3. Model 1: Model geometry for DtS base case.Revision 1-1143'