b'Roof Covering /The products described as DeltaOrb & DeltaTrim when installed at a roof pitch of five degrees or more, complies with the requirements of AS1562.1:2018- Design and Installation of CladdingMetal Roof and Wall Cladding Metal. It follows that the compliance with AS1562.1:2018 then satisfies the requirements of the Building Code of Australia 2022 Volume One deemed to satisfy provision F3D2(b)Roof Covering and Volume Two deemed to satisfy provision H2D6(4)Roof Cladding & H1D7Sheet Roofing. Source: Summermore Pty Ltd; Report titled WEATHER TIGHTNESS CERTIFICATION, dated 30/4/2024.Thermal PropertiesCore Only EPS Core PIR CoreTest thicknessmm102Sample 1Sample 2 Specimen dimensionmm600 x 600Test thicknessmm98.298.7 DensityKg/m317.3Specimen dimensionmm600 x 600600 x 600 Thermal resistancem2K/W2.63DensityKg/m340.242.3 Thermal conductivityW/mK0.0388Thermal resistancem2K/W3.964.25 Thermal conductivityW/mK0.02480.0232 Source: BRANZ Test Report DI11642-001 dated 29/05/2019 Source: BRANZ Test Report DI10856-001-01 dated 04/05/2018. R-Value Calculations Panel Thickness (mm)5075100125150175200225250 DeltaTrim-EPS-FR1.42.02.73.44.14.75.4 DeltaTrim-PIR2.163.234.315.396.477.548.62 DeltaOrb-EPS-FR1.42.02.73.44.14.75.4 DeltaOrb-PIR2.163.234.315.396.477.548.62 DeltaCorroCorro-EPS-FR-1.62.33.13.64.35.05.86.4 DeltaCorroCorro-PIR-2.593.664.965.826.907.979.2710.13 DeltaTrimTrim-EPS-FR-2.02.73.44.14.75.4 DeltaTrimTrim-PIR-3.234.315.396.477.548.62 DeltaTrimCorro-EPS-FR-2.02.73.44.14.75.4 DeltaTrimCorro-PIR-3.234.315.396.477.548.62 The stated R Values are calculated in accordance with AS/NZS 4859.1 & 4859.2:2018 and based on the BRANZ laboratory testing reports DI11642-01 & DI10856-01. Source: R-Value Calculation conducted in accordance with AS/NZS 4859.1 & 4859.2:2018 dated 18/11/2020.Certificate number: CM40309-I02-R02This certificate is only valid when reproduced in its entirety.Page 6 of 7'