b'STEP 6CALCULATE THE UPLIFT ON THE POSTSStep 6.1 Select the Load Width on each Post, refer to the diagram below:SINGLE-SPANFigure A12Load Width - Post 1 = Half (0.5) of A metres + C metersLoad Width - Post 2 = Half (0.5) of A metres + D metersMULTI-SPANFigure A13Load Width - Post 1 = Half (0.5) of A metres + C metersLoad Width - Post 2 = Half (0.5) of A metres + Half (0.5) B metersLoad Width - Post 3 = Half (0.5) of B metres + D meters E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077+61 7 3271 2170 Version Date:50E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077+61 7 3271 2170 Version Date:51ABN: 11 147 861 292W: www.deltapanels.com Sydney Depot:11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 2024-10-01 ABN: 11 147 861 292W: www.deltapanels.com Sydney Depot:11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 2024-10-01'