b'STEP 7POST TO FOOTING SELECTIONTimber Post to Stirrup (see Figure A14)Tabulated Data is in kNFixing Details Footing DetailsNumber of BoltsUplift (kN) Depth of PadD=450mmD=600mmDepth of PadD=450mmD=600mm and Diameter d(mm) (kN) (kN) d(mm) (kN) (kN)2/M10 Bolts 6.75 600 2.25 3.99 1200 4.49 7.982/M12 Bolts 9.65 750 2.81 4.99 1500 5.61 9.982/M16 Bolts 16.7 900 3.37 5.99 1800 6.74 11.981000 3.74 6.65 2000 7.49 13.31Figure A14 E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077+61 7 3271 2170 Version Date:52E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077+61 7 3271 2170 Version Date:53ABN: 11 147 861 292W: www.deltapanels.com Sydney Depot:11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 2024-10-01 ABN: 11 147 861 292W: www.deltapanels.com Sydney Depot:11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 2024-10-01'