b'STEP 9CONNECTION TO HOUSEThrough Fascia Beam (See Figure A40)Part ListITEM QTY PART NUMBER DESCRIPTIONITEM QTY PART NUMBER DESCRIPTION 1 24 90064A580TEK SCREW (SDS) 12-14X206 6 DPP5736 BEAM SPACER 2 1 DPB1001 2.5M DELTABEAM 7 9 HEXBOLT_STEEL_DIN931_ HEX-HEAD BOLT M10X70 DIN931 + NUT3 3 DPB1002 - 300DELTABEAM 8 6 M10 CUP HEAD X 90M10 CUP HEAD X 90 + NUT 4 3 DPB5017 BEAM END CAP 9 3 TIMBER TRUSS WALLTIMBER TRUSS WALL 5 3 DPP1226-XADJUSTABLE FASCIA BRACKET NOTE : A QUALIFIED ENGINEER IS REQUIRED TO CHECK THE STRUCTURAL INTEGRITY OF THE EXISTING ROOFING AND WALL SYSTEM.Figure A40 E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077+61 7 3271 2170 Version Date:78E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077+61 7 3271 2170 Version Date:79ABN: 11 147 861 292W: www.deltapanels.com Sydney Depot:11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 2024-10-01 ABN: 11 147 861 292W: www.deltapanels.com Sydney Depot:11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 2024-10-01'