b'- M W SPECIFICATIONSDeltaOrb-MW is an Insulated Roof Panel System, comprising of two pre-painted, roll-formed steel skins, with a roll-formed steel skins bonded to a non-combustible mineral wool core.The top profile offers striking looks with all of the benefits of modern Insulated Panel technologies.The bottom skin has a roll-formed tongue and groove edge.CodeMark Australia Certificate CM40345 DeltaFireX Car PortSystemincorporatingDeltaOrb-MWpanelscertifies compliance with the stated performance provisions of the NCC2019. Please refer to the certificate, as displayed on our web page, for the exact details of the compliance.CodeMark Australia Certificate CM40346 Class 10a Awning andPatioRoofSystemincorporatingDeltaOrb-MWand DeltaOrb-EPS panels certifies compliance with the stated performance provisions of the NCC2019. Please refer toDetail A Detail Bthe certificate, as displayed on our web page, for the exact details of the compliance. Top Skin 0.42mm / G550 AZ150Steel Skin Details Bottom Skin 0.55mm / G300 Z275Early Fire Hazard Properties AS 1530.3:1999AWTA Test Report 21-003529 19/07/21 Max. Skin Temperature 78 o C Dry HeatIndex Test Range External Top Skin Core Material Details Mineral WoolIgnitability 0-20 0 Thermal Conductivity 0.0363 W/mK @23.0 o CSpread of Flame 0-10 0 AS 1366.2/ASTM C 518Heat Evolved 0-10 0 Core Density 100kg/m 3Smoke Developed 0-10 3 75mm Panel 18.50Combustibility Test AS 1530.1-1994 0.6mm Skin Weight100mm Panel 21.00CSIRO Report no. FNC12604 dated 8/7/2020 tested five (5)(kg/m 2 ) 125mm Panel 23.50samples of the Delta Panels supplied mineral wool sample and150mm Panel 26.00certified that the material is NOT deemed combustible according to the criteria specified in clause 3.4 of AS 1530.1-1994. 75mm Panel 2.08Sotera - FireX Car Port System R Value 100mm Panel 2.78The Sotera report A21007 J005 - DeltaFireX Car Port System FER125mm Panel 3.48dw rev 1-3 (NOTE REV 1-3) confirms that the FireX Car Port150mm Panel 4.17System meets the performance requirements of P2.3.1(a) Volume 2, NCC 2019 Amendment 1 when installed in accordance withCertificate of Conformity CM40435 & CM40436the DeltaFireXRoof Brochure version v15.10.21 and section 4.4 of their report as a Class 10a structure (car port) attached orSheet Coverage 1000mmadjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e.) less than 900 mm from the site boundary) Length (mm) Cut to Length Min of 1800mmSotera - Delta MW and EPS-FR Awning & PatioLength Tolerance (mm) 5mm+/-Roof System Thickness (mm) 75, 100, 125, 150The Sotera report A21007 J004 - Delta MW and EPS-FR Awning andPatioRoofSystemFERdwrev1-3,confirmsthattheBuilding Classes 1-9 - 5Mineral Wool & EPS-FR Awning & Patio Roof System meets theMinimum Roof Pitch Building Class 10- 3performance requirements of P2.3.1(a) Volume 2, NCC 2019 Amendment 1 when installed in accordance with the DeltaSurface deformations can be Mineral Wool Panels Brochure version V20.10.21 and sectionFlatness 0.40mmapparent to the naked eye 4.4 of their report as a Class 10a structure (car port) attached orStandards 0.60mm when observed in certain adjacent to a Class 1a building positioned directly adjacent tolighting conditionsthe site boundary (i.e.) less than 900 mm from the site boundary)Delta Panels Pty Ltd - ABN: 11 147 861 292P: +61 07 3271 2170 Head Office: 731 Boundary Road, Richlands, Qld 4077E: info@deltapanels.comSydney Depot: 11 The Northern Road, Narellan, NSW. 2567 Version Date: 2023-12-19W: www.deltapanels.com'