b'STEP 3 - CUT OUT THE REQUIRED CEILING HOLERefer to the template size on the product information provided.Prior to cutting the hole, double check that the size for the product you are going to install.Remove all insulation in the hole area to a depth of 30mmRemove all insulation from where the light will sit to ensure there is a 10mm air flow gap from the edge of the light fitting. Ensure that this discarded insulation is collected and properly disposed of.DLP120 DLP170STEP 4 - Drill Cable SlotsA 20mm hole is requiredDLP120tobedrilledthrough theEPScorefromthe edge of the panel to the recessed light hole.Theinsulatedcableis fed through this hole.DLP170Delta Panels Pty Ltd - ABN: 11 147 861 292P: +61 07 3271 2170 Head Office: 731 Boundary Road, Richlands, Qld 4077 Page 6 of 8 E: info@deltapanels.comSydney Depot: 11 The Northern Road, Narellan, NSW. 2567 Version Date: 2024-01-10W: www.deltapanels.com'