b'- POLYISOCYANURATE PANELS SAFETY DATA SHEETPRODUCT NAME DELTA PANELS POLYISOCYANURATE PANEL (PIR) -DeltaCoolTM, DeltaSecretFixTM, DeltaTrimTM, DeltaOrbTM, DeltaCorroCorroTM, DeltaTrimTrimTM & DeltaTrimCorroTM5.FIRE FIGHTING MEASURES FlammabilityNon-Flammable, may evoke toxic gases if strongly heated Fire & ExplosionNo fire or explosion hazard exists ExtinguishingPrevent contamination of drains and waterways Hazchem CodeNone Allocated6.ACCIDETAL RELEASE MEASURES SpillageIf the panel is split, collect and reuse if possible Use personal protective equipment Avoid generating dust7.STORAGE AND HANDLING StorageStore in a cool, dry, well ventilated area Store away from moisture, oxidizing agents, acids and foodstuffs Ensure packaging is adequately labelled and protected from damage HandlingCarefully read the product label No Smoking, drinking or eating while using the product Wash hands after use Use good personal hygiene8.EXPOSURE CONTROLS/PERSONAL PROTECTION Components with workplace control parameters IngredientReferenceTWAStel PentaneSWA (AUS)600ppm1770 mg/m3750ppm 2210 mg/m3Biological LimitsNo biological limits allocated Engineering ControlsAvoid Inhalation, use in well ventilated areas If sanding, drilling or cutting use appropriate extraction ventilationPPEPPE is not required under normal working conditions Use Class P1 (Particulate) respirator when sanding, drilling, or cutting Use dust free goggles, and gloves when sanding, drilling, or cuttingPage 2 of 6Version 25. 02. 21 Delta Panels Pty Ltd P: +61 07 3271 2170 E: info@deltapanels.com W: www.deltapanels.com A: 731 Boundary Road, Richlands, Qld 4077 ABN: 11 147 861 292'