b'Delta Panels Mineral Wool - Awning & PatiosTECHNICAL SPECIFICATIONS FIRE TEST PERFORMANCETop Skin 0.42mm / G550 AZ150 Combustibility Test AS 1530.1-1994Steel Skin Details Roof Bottom Skin 0.55mm / G300 Z275CSIRO Report no. FNC12604 dated 8/7/2020 tested Max. Skin Temperature 78 o C Dry Heat five (5) samples of the Delta Panels supplied mineral Core Material Details Mineral Wool wool sample and certified that the material is NOT deemedcombustibleaccordingtothecriteria Thermal Conductivity 0.042 W/mK @23.0 o C specified in clause 3.4 of AS 1530.1-1994.Core Density 100kg/m 3 Sotera - FireX Car Port System75mm Panel 18.50 The Sotera report A21007 J005 - DeltaFireX Car Port 0.6mm Skin Weight100mm Panel 21.00(kg/m 2 ) 125mm Panel 23.50 System FER dw rev 1-3 confirms that the FireX Car 150mm Panel 26.00 Port System meets the performance requirements of P2.3.1(a) Volume 2, NCC 2019 Amendment 1 when 75mm Panel 2.50 installedinaccordancewiththeDeltaFireXRoof 100mm Panel 3.30 Brochure version v15.10.21 and section 4.4 of their R Value 125mm Panel 4.20 report as a Class 10a structure (car port) attached 150mm Panel 5.00 or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e.) less than 900 mm Certificate of Conformity CM40436 from the site boundary)Sheet Coverage 1000mm - Roof Sotera - Delta MW and Length (mm) Cut to Length Min of 1800mm EPS-FR Awning & Patio Roof SystemLength Tolerance (mm) 5mm+/- TheSoterareportA21007J004-DeltaMWand EPS-FRAwningandPatioRoofSystemFERdw Thickness (mm) 75, 100, 125, 150 rev1-3,confirmsthattheMineralWool&EPS-FR Surface deformationsAwning & Patio Roof System meets the performance can be apparent torequirementsofP2.3.1(a)Volume2,NCC2019 Flatness 0.55mm the naked eye whenAmendment 1 when installed in accordance with the Standards observed in certainDelta Mineral Wool Panels Brochure version V20.10.21 lighting conditions and section 4.4 of their report as a Class 10a structure (car port) attached or adjacent to a Class 1a building DeltaTrim TMFixing Details positioned directly adjacent to the site boundary (i.e.) Crest fixing only. One fixing every second crest less than 900 mm from the site boundary)Panel Thickness (mm) Fixing into Steel75 Tek 14 x 150 Hex Head Screw Early Fire Hazard PropertiesAS 1530.3 1989100 Tek 14 x 175 Hex Head Screw AWTA Test Reports 21-003527 & 21-003529125 Tek 14 x 200 Hex Head Screw Index Test Range External Top Skin150 Tek 14 x 230 Hex Head Screw Ignitability 0-20 0DeltaOrb TMFixing Details Spread of Flame 0-10 0Crest fixing only. One fixing every second crest Heat Evolved 0-10 0Panel Thickness (mm) Fixing into Steel Smoke Developed 0-10 375 Tek 14 x 135 Hex Head Screw100 Tek 14 x 150 Hex Head Screw125 Tek 14 x 175 Hex Head Screw150 Tek 14 x 200 Hex Head ScrewDelta Panels Pty LtdP: +61 07 3271 2170E: info@deltapanels.com W: www.deltapanels.comA: 731 Boundary Road, Richlands, Qld 4077 ABN: 11 147 861 292'