b'-MW SPECIFICATIONSDeltaCool-MW Single Span TablesSpan Pressure (kPa)mm 75mm 100mm 150mm1800 2.47 3.30 5.00 Detail A2400 1.93 2.57 4.013000 1.43 1.90 2.99 0.60mm DeltaCool-MW Bracing Capacity3600 1.18 1.57 2.40 Panel Height (m) 2.4 1.2* 4.8*4200 1.02 1.35 2.03 Kn/m 5.0 10.0 2.54800 0.85 1.13 1.69 Bracing Units (BU) 100 200 505400 0.71 0.94 1.416000 0.60 0.80 1.20 * Figures for 1.2m & 4.8m high panels are extrapolated.ItisacceptabletoextrapolateBracingCapacityheights between 1.2m & 4.8m. For heights outside of this dimension range,DiaphragmAnalysisisrequiredtoestablishBracing DeltaCool-MW Multi Span Tables Capacity.Shear Load Transference - Shear load is transferred by rivets Span Pressure (kPa) into the floor / ground surface or the perpendicular walls, ceiling mm 75mm 100mm 150mm & roof at a rate of 1.21 kN per 4.0 mm diameter rivet.1800 1.98 2.64 3.96 Fixing rivets at 200mm centres complies with the 20-minute flamebarrierrequirementsanddelivers14.5kNofshear 2400 1.55 2.06 3.09 capacity transfer per panel (6 on each side) horizontally, and 12.1 kN per metre in vertical joints. Limited by the ability of the 3000 1.14 1.52 2.28 panel to transfer the shear.3600 0.95 1.25 1.884200 0.83 1.09 1.64 Acoustic Values4800 0.71 0.94 1.41 AcousticTestinghasbeenperformedincompliancewith therequirementsofAS1191-2002Acoustics-Methodfor 5400 0.62 0.82 1.23 LaboratoryMeasurementofAirborneSoundInsulationof Building Elements.6000 0.57 0.76 1.14 TheproceduresspecifiedbyAS/NZSISO717.1:2024were used to calculate the Sound Transmission Class (STC) and the DeltaCool-MW Internal Application Weighted Sound Reduction Index Rw = 25 dB.Span Pressure (kPa)Handling & Installationmm 75mm 100mm 150mm DeltaCool-MWcorematerialisfibrousassuchitiseasy tofracturethemineralwoolfibresifhandledandinstalled Walls 7300 8500 9600 incorrectly. Please ensure that correct lifting equipment is used (Non Load Bearing) when the panels are transported and lifted into position. Refer to Ceilings 3500 4500 4200 the Handling & Installation Manual - Wall Systems for the correct Crane & Sling Procedures. AsatthestatedVersionDatealloftheinformation containedinthisdocumentiscorrect.Pleasecheck on our WebPage to ensure that youre referencing the current version. Delta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2025-12-04W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'