b'-TPCSPECIFICATIONSSingle Spans (mm)WindPanel3 Sides2 Sides1 SideFully Category Thickness Open Open Open Enclosed75 7380 5630 4190 5250 Detail AN2 (W33) 100 7500 68860 4900 6330150 9000 7780 5740 7230 Acoustic Performance75 5270 4070 3060 3810 Acoustic testing has been performed on TPC panels incompliance with the requirements of AS 1191-2002 Acoustics - Method for N3 (W41) 100 6360 4740 3430 4390 Laboratory Measurement of Airborne Sound Insulation of Building Elements.150 7270 5570 4150 5190 The procedures specified by AS/NZS ISO 717.1:2024 were used to calculate the Sound Transmission Class (STC) and the Weighted 75 3960 3080 2330 2880 Sound Reduction Index Rw = 25 dB.N4 100 4590 3450 2510 3200(W50)150 5410 4170 3130 3900 Trafficable StatusDeltaOrb-TPCisclassifiedastrafficablewhenusedfor DeltaOrb-TPC Acoustic Values maintenance purposes. The following recommendations should be observed at all times.50mm 125mmWear flat, rubber soled shoes Walk over the roof supporting beams100 15.41 15.00Spread your weight over as many roof crests as possibleCrawl boards should be used when accessing areas not 160 16.40 15.09supported by a structure200 18.81 17.70250 19.70 18.51 DeltaOrb-TPC Fixing Details315 21.39 19.40 Crest fixing only. One fixing every second crestPanel 400 22.31 19.69 ThicknessFixing into Steel Fixing into Timber(mm)630 23.40 19.10 50 Tek 14 x 115 Hex Head Screw T17 14 x 125 Hex Head Screw800 23.69 17.31Frequency 1000 25.61 18.29 75 Tek 14 x 135 Hex Head Screw T17 14 x 150 Hex Head Screw1250 21.01 30.10 100 Tek 14 x 150 Hex Head Screw T17 14 x 175 Hex Head Screw1600 20.00 36.19 125 Tek 14 x 175 Hex Head Screw T17 14 x 200 Hex Head Screw2000 34.79 37.30 150 Tek 14 x 200 Hex Head Screw T17 14 x 230 Hex Head Screw2500 41.70 37.093150 44.10 35.69 175 Tek 14 x 230 Hex Head Screw T17 14 x 265 Hex Head Screw5000 44.61 39.90 200 Tek 14 x 260 Hex Head Screw T17 14 x 300 Hex Head ScrewSTC 24.00 23.00 Use Cyclone Plate and Neo Washer on each fixing.RW 25.00 24.00 Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.As at the stated Version Date all of the information contained in this document is correct. Please check on our WebPage to ensure that youre referencing the current version. Delta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2024-11-28W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'