b'DeltaCorroCorro-EPS-FRAcoustic PerformanceDeltaCorroCorro-EPS-FR Acoustic Testing has been performed Detail B in compliance with the requirements of AS 1191-2002 Acoustics -MethodforLaboratoryMeasurementofAirborneSound Insulation of Building Elements.Early Fire Hazard Properties AS 1530.3:1999 TheproceduresspecifiedbyAS/NZSISO717.1:2024were AWTA Test Report 18-006076 14-11-2018 used to calculate the Sound Transmission Class (STC) and the Weighted Sound Reduction Index Rw = 25 dB.Index Test Range External Top SkinIgnitability 0-20 0 Trafficable StatusSpread of Flame 0-10 0 DeltaCorroCorro-EPS-FRis classified as trafficable when used Heat Evolved 0-10 0 formaintenancepurposes.Thefollowingrecommendations should be observed at all times.Smoke Developed 0-10 2 Wear flat, rubber soled shoesWalk over the roof supporting beamsSpread your weight over as many roof crests as possibleSingle Spans (mm)Crawl boards should be used when accessing areas not WindPanel3 Sides2 Sides1 SideFullysupported by a structureCategory Thickness Open Open Open Enclosed75 4900 4900 4900 4900 DeltaCorroCorro-EPS-FR Fixing DetailsN2 (W33) 100 6300 6300 6300 6300 Crest fixing only. One fixing every second crest125 7600 7600 7600 7600 Panel ThicknessFixing into Steel Fixing into Timber75 4800 4400 4000 4000 (mm)N3 (W41) 100 6000 5600 5100 5100 75 Tek 14 x 115 Hex Head Screw T17 14 x 125 Hex Head Screw125 7300 6700 6100 6100 100 Tek 14 x 135 Hex Head Screw T17 14 x 150 Hex Head Screw75 4000 3500 3200 3200 125 Tek 14 x 150 Hex Head Screw T17 14 x 175 Hex Head ScrewN4 100 5000 4600 4200 4200(W50) 150 Tek 14 x 175 Hex Head Screw T17 14 x 200 Hex Head Screw125 6000 5600 5000 5000175 Tek 14 x 200 Hex Head Screw T17 14 x 230 Hex Head ScrewDeltaCorroCorro-EPS-FR Acoustic Values 200 Tek 14 x 230 Hex Head Screw T17 14 x 265 Hex Head Screw50mm 125mm 225 Tek 14 x 260 Hex Head Screw T17 14 x 265 Hex Head Screw100 15.41 15.00200 18.81 17.70 250 Tek 14 x 300 Hex Head Screw T17 14 x 300 Hex Head Screw400 22.31 19.69 Use Cyclone Plate and Neo Washer on each fixing.800 23.69 17.31 Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.Frequency 1000 25.61 18.29 As at the stated Version Date all of the information contained 1250 21.01 30.10 in this document is correct. Please check on our WebPage 2000 34.79 37.30 to ensure that youre referencing the current version. 2500 41.70 37.095000 44.61 39.90STC 24.00 23.00RW 25.00 24.00Delta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2024-11-24W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'