b'Limits For Using Type 1P Awning Classification.Following are the dimensional requirements for using Type 1P awning classification, which has 1 partial wall.For awning dimensions, refer to figure 1.Awning is to be attached one side only to an existing building.Awning pitchis to be between 1 and 10.Slope of the awning is to be normal to the attached wall.Minimum hc = 0.05 x dMaximum hc = 1.0 x dMaximum hc/wc to be as per Table 1.Maximum blockage under the roof parallel to the attached wall is to be 56% of the projected area. Awnings attached one side that do not comply with the above are to be classified as Type 1. Maximum hc = 1.0 x dMaximum hc/wc to be as per Table 1.Maximum blockage under the roof parallel to the attached wall is to be 56% of the projected area. Awnings attached one side that do not comply with the above are to be classified as Type 1. Figure 1 - Roof DimensionDelta Panels Pty LtdP: +61 7 3271 2170 E: info@deltapanels.com W: www.deltapanels.comA: 731 Boundary Road, Richlands, Qld 4077 ABN: 11 147 861 292'