b'-MW SPECIFICATIONSDetail CDeltaSecretFix-MW Single Span Tables 0.60mm DeltaSecretFix-MW Bracing CapacitySpan Pressure (kPa) Panel Height (m) 2.4 1.2* 4.8*mm 75mm 100mm 150mm Kn/m 5.0 10.0 2.51800 2.47 3.30 5.00 Bracing Units (BU) 100 200 502400 1.93 2.57 4.01 * Figures for 1.2m & 4.8m high panels are extrapolated.ItisacceptabletoextrapolateBracingCapacityheights 3000 1.43 1.90 2.99 between 1.2m & 4.8m. For heights outside of this dimension range,DiaphragmAnalysisisrequiredtoestablishBracing 3600 1.18 1.57 2.40 Capacity.4200 1.02 1.35 2.03 Shear Load Transference- Shear load is transferred by rivets 4800 0.85 1.13 1.69 into the floor / ground surface or the perpendicular walls, ceiling & roof at a rate of 1.21 kN per 4.0 mm diameter rivet.5400 0.71 0.94 1.41 Fixing rivets at 200mm centres complies with the 20-minute 6000 0.60 0.80 1.20 flamebarrierrequirementsanddelivers14.5kNofshear capacity transfer per panel (6 on each side) horizontally, and 12.1 kN per metre in vertical joints. Limited by the ability of the DeltaSecretFix-MW Multi Span Tables panel to transfer the shear.Span Pressure (kPa) Acoustic Valuesmm 75mm 100mm 150mm AcousticTestinghasbeenperformedincompliancewith 1800 1.98 2.64 3.96 the requirements of AS 1191-2002 Acoustics - Method for LaboratoryMeasurementofAirborneSoundInsulationof 2400 1.55 2.06 3.09 Building Elements.3000 1.14 1.52 2.28 The procedures specified by AS/NZS ISO 717.1:2024 were used to calculate the Sound Transmission Class (STC) and the 3600 0.95 1.25 1.88 Weighted Sound Reduction Index Rw = 25 dB.4200 0.83 1.09 1.64Handling & Installation4800 0.71 0.94 1.41 DeltaSecretFix-MW core material is fibrous as such it is easy 5400 0.62 0.82 1.23 tofracturethemineralwoolfibresifhandledandinstalled 6000 0.57 0.76 1.14 incorrectly. Please ensure that correct lifting equipment is used when the panels are transported and lifted into position. Refer to the Handling & Installation Manual - Wall Systems for the correct DeltaSecretFix-MW Internal Application Crane & Sling Procedures. Span Pressure (kPa) As at the stated Version Date all of the information contained in this document is correct. Please check on our WebPage mm 75mm 100mm 150mm to ensure that youre referencing the current version. Walls 7300 8500 9600(Non Load Bearing)Ceilings 3500 4500 4200Delta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2025-12-04W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'