b'-PIR SPECIFICATIONSDeltaSecretFix-PIR Single Span Non-Cyclonic TablesSpan Pressure (kPa) 0.60mm DeltaSecretFix-PIR Bracing Capacitymm 50mm 75mm 100mm Panel Height (m) 2.4 1.2* 4.8*2000 1.93 2.52 3.07 Kn/m 5.0 10.0 2.52400 1.60 2.10 2.50 Bracing Units (BU) 100 200 503000 1.17 1.62 1.93 * Figures for 1.2m & 4.8m high panels are extrapolated. It is acceptable to extrapolate Bracing Capacity heights between3600 0.77 1.19 1.49 1.2m & 4.8m.For heights outside of this dimension range, Diaphragm Analysis is required to establish Bracing Capacity.4200 0.52 0.89 1.19 Shear Load Transference - Shear load is transferred by rivets 4800 0.33 0.68 0.96 into the floor / ground surface or the perpendicular walls, ceiling & roof at a rate of 1.21 kN per 4.0 mm diameter rivet.5400 0.25 0.55 0.82 Fixing rivets at 200mm centres complies with the 20-minute flamebarrierrequirementsanddelivers14.5kNofshear 6000 0.19 0.47 0.72 capacity transfer per panel (6 on each side) horizontally, and 12.1 kN per metre in vertical joints. Limited by the ability of the panel to transfer the shear.DeltaSecretFix-PIR Multi SpanIf a higher level is required, it is necessary to stitch the joints, Non-Cyclonic Tables with each 4.0mm diameter rivet providing 1.21 kN in shear in Span Pressure (kPa) the slip joint.mm 50mm 75mm 100mm DeltaSecretFix-PIR Acoustic Values2000 1.74 2.22 3.082400 1.50 1.90 2.59 50mm 125mm3000 1.17 1.57 2.07 Frequency STC 24.00 23.003600 0.90 1.27 1.68 RW 25.00 24.004200 0.66 1.00 1.354800 0.47 0.77 1.125400 0.37 0.60 0.906000 0.31 0.48 0.69Version Date: 15.12.2020Delta Panels Pty Ltd Delta Panels Pty LtdP: +61 07 3271 2170E: info@deltapanels.com W: www.deltapanels.comA: 731 Boundary Road, Richlands, Qld 4077 ABN: 11 147 861 292 P: +61 07 3271 2170E: info@deltapanels.com W: www.deltapanels.comA: 731 Boundary Road, Richlands, Qld 4077 ABN: 11 147 861 292'