b'1.TEST SPONSOR Delta Panels Pty Ltd 2828 Ipswich Road, Darra, Brisbane, 4076, Australia 2.LIMITATION The results reported here relate only to the item/s tested. 3.TERMS AND CONDITIONS This report is issued in accordance with the Terms and Conditions as detailed and agreed in the BRANZ Services Agreement for this work. 4.DESCRIPTION OF TEST EQUIPMENT The test equipment used was a LaserComp Fox 600 heat flow meter.The specimen for testing is placed horizontally in the apparatus, with upwards heat flow.The hot and cold plates each have a 250 mm x 250 mm heat flux transducer embedded in their surface.The edges of the specimen are insulated from the room ambient temperature. 5.PROCEDURE The specimen was supplied by the client and consisted ofone piece of white expanded polystyrene insulation segment.The dimensions of the sample were 600 x 600 mm.It was tested at the actual thickness, to the requirements of ASTM C518.6.RESULTS Table 1 Test condition set-points Nominal Upper Plate Temperature10.0C Nominal Lower Plate Temperature36.0C Nominal Difference in Temperature26.0K Nominal Mean Temperature23.0C REPORT NUMBER:ISSUE DATE:PAGE:DI11689-001-0118 June 20194 of 5 branz.nz | 1222 Moonshine Rd, RD1, Porirua 5381, Private Bag 50 908, Porirua 5240, New ZealandPhone +64 4237 1170branz@branz.co.nz'