b'Delta Panels Mineral Wool - Awning & PatiosTECHNICAL SPECIFICATIONS FIRE TEST PERFORMANCETop Skin 0.42mm / G550 AZ150 Fire Test Certificate - AS ISO 9705Steel Skin Details Roof Bottom Skin 0.55mm / G300 Z275 Group 1Classification in accordance with NCC 2022 Max. Skin Temperature 78 o C Dry Heat Volume One Amendment 2 Clause C2D11 & Clause S7C4 determined in accordance with AS 5637.1:2015 as per Core Material Details Mineral Wool Jensen Hughes test report 252674 issued 28 November 2025 & Spectra Fire Engineers report 25367 issued 25 Thermal Conductivity 0.042 W/mK @23.0 o C November 2025Core Density 100kg/m 3 Combustibility Test AS 1530.1-199475mm Panel 18.50 CSIRO Report no. FNC12604 dated 8/7/2020 tested five 0.6mm Skin Weight100mm Panel 21.00 (5) samples of the Delta Panels supplied mineral wool (kg/m 2 ) 125mm Panel 23.50 sample and certified that the material is NOT deemed combustible according to the criteria specified in clause 150mm Panel 26.00 3.4 of AS 1530.1-1994.75mm Panel 2.50100mm Panel 3.30 Sotera - FireX Car Port SystemR Value 125mm Panel 4.20 TheSoterareportA21007J005-DeltaFireXCarPort 150mm Panel 5.00 System FER dw rev 1-4 confirms that the FireX Car Port SystemmeetstheperformancerequirementsofH3P1 Certificate of Conformity CM40436 Volume 2, NCC 2022 Amendment 2 when installed in accordance with the DeltaFireX Roof Brochure version Sheet Coverage 1000mm - Roof v25.12.04 and section 4.4 of their report as a Class 10a structure (car port) attached or adjacent to a Class 1a Length (mm) Cut to Length Min of 1800mm building positioned directly adjacent to the site boundary (i.e.) less than 900 mm from the site boundary)Length Tolerance (mm) 5mm+/-Thickness (mm) 75, 100, 125, 150 Sotera - Delta MW and EPS-FR Awning & Patio Roof SystemSurface deformationsThe Sotera report A21007 J004 - Delta MW and EPS-FR Flatness can be apparent toAwning and Patio Roof System FER dw rev 1-4, confirms Standards 0.55mm the naked eye whenthat the Mineral Wool & EPS-FR Awning & Patio Roof observed in certainSystemmeetstheperformancerequirementsofH3P1 lighting conditions Volume 2, NCC 2022 Amendment 2 when installed in accordance with the Delta Mineral Wool Panels Brochure DeltaTrim TMFixing Details version v25.12.04 and section 4.4 of their report as a Crest fixing only. One fixing every second crest Class 10a structure (car port) attached or adjacent to a Class 1a building positioned directly adjacent to the site Panel Thickness (mm) Fixing into Steel boundary (i.e.) less than 900 mm from the site boundary)75 Tek 14 x 150 Hex Head Screw100 Tek 14 x 175 Hex Head Screw Early Fire Hazard PropertiesAS 1530.3 1989125 Tek 14 x 200 Hex Head Screw AWTA Test Reports 21-003527 & 21-003529150 Tek 14 x 230 Hex Head Screw Index Test Range External Top SkinIgnitability 0-20 0DeltaOrb TMFixing Details Spread of Flame 0-10 0Crest fixing only. One fixing every second crest Heat Evolved 0-10 0Panel Thickness (mm) Fixing into Steel Smoke Developed 0-10 375 Tek 14 x 135 Hex Head Screw100 Tek 14 x 150 Hex Head Screw125 Tek 14 x 175 Hex Head Screw150 Tek 14 x 200 Hex Head ScrewDelta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 07 3271 2170 Version Date: 2025-12-04W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 02 4611 7712'