b'A3 Product specification Fire HazardIgnitabilitySpread ofHeat EvolvedSmokeGroup Number PropertiesIndexFlame IndexIndexDeveloped IndexClassification C2D11(1)(i)EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. |0000-1Group 1 DeltaCore Density 13.5kgm3 CorroCorroTPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite0003Group 1 core. | Core Density 36kgs/m3 EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. |0002Group 1 Core Density 13.5kgm3 Delta TrimTPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m 0001Group 1 3EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | DeltaCore Density 13.5kgm30003Group 1 TrimTrimTPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m 0001Group 1 3EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | DeltaCore Density 13.5kgm30000-1- TrimCorro-TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m 0003- 3EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. |Group 1 Delta OrbCore Density 13.5kgm30002 TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite0000-1Group 1 core. | Core Density 36kgs/m3 The specimens were tested in accordance with Specification 3 & 7Fire Hazard Properties, however no perforations, recesses or the likes were tested and sit outside of the scope of certification. Bushfire AttackFor the purpose of building regulations in Australia, the test specimen achieved a Bushfire Attack Level (BAL) of AA29. Level (BAL)This report details the methods of construction, the test conditions and the results obtained when the specific element of construction described herein was tested in accordance with the test method of AS 1530.8.1. NOTE: Bushfire Attack Level (BAL) results are limited to the TPC core panel only. Source: CSIRO (Infrastructure Technologies); Report titled Bushfire test on a roof system, dated 21/12/2023 Roof Covering /The products described as DeltaOrb & DeltaTrim when installed at a roof pitch of five degrees or more, complies with the requirements of AS1562.1:2018- Design and Installation of Metal CladdingRoof and Wall Cladding Metal. It follows that the compliance with AS1562.1:2018 then satisfies the requirements of the Building Code of Australia 2022 Volume One deemed to satisfy provision F3D2(b)Roof Covering and Volume Two deemed to satisfy provision H2D6(4)Roof Cladding & H1D7Sheet Roofing. Source: Summermore Pty Ltd; Report titled WEATHER TIGHTNESS CERTIFICATION, dated 30/4/2024.Certificate number: CM40309-I03-R00This certificate is only valid when reproduced in its entirety.Page 5 of 7'