b'ThermalEPS CorePropertiesAustraliaTotal R-value [(m.K)/W] (Summer/Winter) &System U0value [W/(m.K)] (Summer/Winter) EPS(SL)Thickness (mm)5075100125150175200250 External RoofR (Sum.)1.361.852.433.023.564.154.685.27 U (Sum.) 0.740.540.410.330.280.240.210.19 R (Wint.) 1.381.902.523.133.694.314.885.49 U (Wint.) 0.720.530.400.320.270.290.200.18 Source: Acronem Consulting Australia Pty Ltd, DELTA PANELS Thermal Performance Letter EPS, dated 22/02/2024TPC CoreAustraliaTotal R-value [(m.K)/W] (Summer/Winter) &System U0value [W/(m.K)] (Summer/Winter) TPCThickness (mm)506070758090100110125150175200 External RoofR (Sum.)1.451.701.952.052.202.402.652.953.303.904.605.20 U (Sum.) 0.690.590.510.450.450.420.380.340.300.260.220.19 R (Wint.) 1.451.702.002.252.252.502.753.053.404.054.755.40 U (Wint.) 0.690.590.500.440.440.400.360.330.290.250.210.19 Source: Acronem Consulting Australia Pty Ltd, DELTA PANELS Thermal Performance Letter TPC, dated 08/10/2024.A4 Manufacturer and manufacturing plant(s) Delta Panels Pty Ltd 2828 Ipswich Road, Darra QLD 4076. A5 Installation requirements Installation must be in accordance with the following documentation: Handling & Installation Manual Delta Panels Roofing Systems V2025.12.01Module A - Awnings, Patios & Carports Engineering & Construction Manual Non Cyclonic & Cyclonic Regions Doc 180509 V2025-11-25. Flashings - Recommended Installation Doc 180520 V.2023-10-27. A6 Other relevant technical data No other relevant technical data.Certificate number: CM40309-I03-R00This certificate is only valid when reproduced in its entirety.Page 6 of 7'