b'-MW SPECIFICATIONSDeltaTrim-MWisanInsulatedRoofPanelSystem, comprisingoftwopre-painted,withroll-formedsteel skins boned to a non-combustible mineral wool core.CodeMark Australia Certificate CM40345 DeltaFireX Car Port System incorporating DeltaTrim-MW panels certifies compliance with the stated performance provisions of the NCC 2022Amendment 2 . Please refer to the certificate, as displayed on our web page, for the exact details of the compliance.CodeMark Australia Certificate CM40346 Class 10a Awning and Patio Roof System incorporating DeltaTrim-MW and DeltaTrim-EPS panels certifies compliance with the stated performance provisions of the NCC 2022Amendment 2 .Detail A Detail BPlease refer to the certificate, as displayed on our web page, for the exact details of the compliance. Top Skin 0.42mm / G550 AZ150Fire Test Certificate - AS ISO 9705 Steel Skin Details Bottom Skin 0.55mm / G300 Z275Group 1 Classification in accordance with NCC 2022 VolumeMax. Skin Temperature 78oC Dry HeatOne Amendment 2 Clause C2D11 & Clause S7C4 determined in accordance with AS 5637.1:2015 as per Jensen HughesCore Material Details Mineral Wooltest report 252674 issued 28 November 2025 & Spectra Fire Engineers report 25367 issued 25 November 2025 Thermal Conductivity 0.0365 W/mK @23.0oCAS 1366.2/ASTM C 518Combustibility Test AS 1530.1-1994 Core Density 100kg/m 3CSIRO Report no. FNC12604 dated 8/7/2020 tested five (5) samples of the Delta Panels supplied mineral wool sample75mm Panel 18.50and certified that the material is NOT deemed combustiblePanel Weight (kgs/m 2 )100mm Panel 21.00accordingtothecriteriaspecifiedinclause3.4ofASbased on 0.6mm steel 1530.1-1994. skins 125mm Panel 23.50150mm Panel 26.00Sotera - FireX Car Port System Thickness Winter (15o ) Summer (30o )The Sotera report A21007 J005 - DeltaFireX Car Port System75mm Panel 2.40 2.25FER dw rev 1-4 confirms that the FireX Car Port SystemExternal Roofmeets the performance requirements of H3P1 Volume 2,R Value (m 2 .K/W)100mm Panel 3.10 2.95NCC2022Amendment2wheninstalledinaccordanceAS/NZS 4859 Parts 1 & with the DeltaFireX Roof Brochure version V25.12.04 and2:2018 125mm Panel 3.80 3.60section 4.4 of their report as a Class 10a structure (car150mm Panel 4.55 4.25port) attached or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e.) less than 900 mm from the site boundary) Certificate of Conformity CM40435 & CM40436Sotera - Delta MW and EPS-FR Awning &Sheet Coverage 1000mmPatio Roof System Length (mm) Cut to Length Min of 1800mmThe Sotera report A21007 J004 - Delta MW and EPS-FRLength Tolerance (mm) 5mm+/-Awning and Patio Roof System FER dw rev 1-4, confirms thattheMineralWool&EPS-FRAwning&PatioRoof SystemmeetstheperformancerequirementsofH3P1Thickness (mm) 75, 100, 125, 150Volume2,NCC2022Amendment2wheninstalledin accordance with the Delta Mineral Wool Panels BrochureMinimum Roof Pitch 2oversion V25.12.04 and section 4.4 of their report as a Class 10a structure (car port) attached or adjacent to a Class 1aSurface deformations can be building positioned directly adjacent to the site boundaryFlatness 0.40mmapparent to the naked eye when (i.e.) less than 900 mm from the site boundary) Standards 0.60mm observed in certain lighting conditionsDelta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2025-12-04W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'