b'-MW SPECIFICATIONS Handling & InstallationDeltaTrim-MWcorematerialisfibrousassuchitis easy to fracture the mineral wool fibres if handled and installed incorrectly.Please ensure that correct lifting equipment is used when the panels are transported and Detail A lifted into position. Refer to the Handling & Installation Early Fire Hazard Properties AS 1530.3:1999 Manual - Roof Systems for the correct Crane & Sling AWTA Test Report 21-003527 19/07/21 Procedures. When installing Mineral Wool panels only Index Test Range External Top Skin step onto the section of the panels that are supported bytheunderneathroofstructure.Donotstepon Ignitability 0-20 0 unsupportedspans.Onceinstalleditisclassifiedas Spread of Flame 0-10 0 trafficable when used for maintenance purposes. The following recommendations should be observed at all Heat Evolved 0-10 0 times.Smoke Developed 0-10 3Wear flat, rubber soled shoes Walk over the roof supporting beams Spread your weight over as many roof crests as possibleDeltaTrim-MW Spanning RecommendationCrawl boards should be used when accessing areas Due to the friable nature of Mineral Wool we recommend that the not supported by a structuremaximum unsupported spanning is:-75mm - 2500mm 100mm - 2500mm125mm - 3000mm 150mm - 3000mm Aesthetics Roll-formed metal sheeting as utilised in DeltaTrim Acoustic Values InsulatedPanelsmayexhibitwaviness,commonly referred to as oil-canning. The degree of oil-canning AcousticTestinghasbeenperformedincompliancewithwill vary depending on factors such as thepanels the requirements of AS 1191-2002 Acoustics - Method forlength, colour and exposure to sunlight. Oil-canning LaboratoryMeasurementofAirborneSoundInsulationofpertains to aesthetics only and has no adverse effect Building Elements. onthestructuralperformanceofthepanels.Delta Panels is not responsible for oil-canning or aesthetics. The procedures specified by AS/NZS ISO 717.1:2024 wereOil-canning shall not be grounds to withhold payment used to calculate the Sound Transmission Class (STC) andor reject panels.the Weighted Sound Reduction Index Rw = 25 dB.DeltaTrim-MW Fixing DetailsCrest fixing only. One fixing every second crestPanel ThicknessFixing into Steel Fixing into Timber(mm) As at the stated Version Date all of the information contained in this 75 Tek 14 x 150 Hex Head Screw T17 14 x 150 Hex Head Screw document is correct. Please check on our WebPage to ensure that 100 Tek 14 x 175 Hex Head Screw T17 14 x 175 Hex Head Screw youre referencing the current version. Please refer to the web page for the available colour range, paint 125 Tek 14 x 200 Hex Head Screw T17 14 x 200 Hex Head Screw finishes and relevant warranty conditions.150 Tek 14 x 230 Hex Head Screw T17 14 x 230 Hex Head ScrewUse Cyclone Plate and Neo Washer on each fixing.Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.Delta Panels Pty Ltd - ABN: 11 147 861 292E: info@deltapanels.comHead Office: 731 Boundary Road, Richlands, Qld 4077P: +61 7 3271 2170 Version Date: 2025-12-04W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712'