b'Certificate number: CM40330Certification Body: THIS IS TO CERTIFY THAT DeltaTrim DualCore & DeltaOrb DualCore Panels ABN: 81 663 250 815 JAS-ANZ AccreditationType and/or use of product:Description of product:No. Z4450210AKRoof panel for Non-Habitable Buildings and Structures are situated within 900mm of a siteTwo pre-painted, roll-formed steel DeltaTrim or DeltaOrb skins bonded to a Mineral Wool PO Box 273, Palmwoods Qld 4555boundary and attached or adjacent to a Class 1a building. (minimum coverage 900mm) and fire retardant SL Grade Expanded Polystyrene core (EPS). Refer A2 Australiafor more information.P: +61 7 5445 2199 www.cmicert.com.au COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S)BCA 2022 office@cmicert.com.au Volume OneVolume TwoPerformance Requirement(s):Not ApplicableH3P1(1)Will contribute to Spread of fire subject to the Limitations and Certificate Holder:conditions below.Deemed-to-Satisfy Provision(s):Not Applicable Not Applicable Delta Panels Pty LtdState or territory variation(s): Not Applicable Not ApplicableABN: 11 147 861 292SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B 731 Boundary Road, Richlands, QLD, 4077 Limitations and conditions:Building classification/s: Australia1.Compliance with Contributes towards Compliance with H3P1(1) is subject to site specific performance solution to the satisfaction of the Appropriate Authority as describedClass 10aPh: 07 3271 2170by the NCC.www.deltapanels.com.au2.The portion of the roof system which is located within 900 mm of a site boundary shall consist solely of non-combustible components (subject to (d)) including:i.Mineral woolii.Pre-finished steel sheeting with combustible surface finish not exceeding 1 mm thickness and with a spread of flame index no greater than 0 in accordance with NCC Clause H3D3.iii.Steel fixtures, gutters and the likeiv. Steel columns, beams, purlins and the like v. Metallic flashing b.As the DeltaDualCore panel constitutes a bonded laminate, the following restrictions shall apply to the portion of the panel that is within 900mm of the site boundary:i.The laminas shall be restricted to steel facings with mineral wool core, each of which has been tested to AS 1530.1 and are deemed non-combustible. ii.Each adhesive layer may not exceed 1 mm in thickness and the total combined thickness of adhesive layers may not exceed 2mm. iii. The spread of flame index and the smoke developed index of the bonded laminated material as a whole shall not exceed 0 and 3 respectively. Date of issue: 11/09/2024 Richard Donarski - CMIDon GrehanUnrestricted Building CertifierDate of expiry: 28/09/2027Certificate number: CM40330-I02-R00This certificate is only valid when reproduced in its entirety.Page 1 of 4'