b'A3 Product specification Spread of FireDeltaTrimDualCore & DeltaOrbDualCore Panels meet the performance requirements of H3P1 Volume 2, NCC 2022 when installed in accordance with the DeltaDualCore_brochure_V24-08-22 and Section 4.4 (SOTERA Pty Ltd; Fire Engineers Report; DeltaDualCore Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023) as a Class 10a structure (awning or patio) attached or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e. less than 900 mm from the site boundary). The comparative assessment has demonstrated qualitatively and quantitatively that the DeltaDualCore system (when installed to the requirements of Section 4.4 (SOTERA Pty Ltd; Fire Engineers Report; DeltaDualCore Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023) does not increase the risk of fire spread from or to an associated Class 1 building when compared to the DtS base case. Performance requirement H3P1 is satisfied. The assessment is compliant in accordance with A2G2 (1)(b) and A2G2(2)(d).Source: SOTERA Pty Ltd; Fire Engineers Report; DeltaDualCore Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023. A4 Manufacturer and manufacturing plant(s) Delta Panels Pty Ltd 731 Boundary Road, Richlands, QLD 4077. A5 Installation requirements Installation must be in accordance with the DeltaDualCore_brochure_V24-07-03 A6 Other relevant technical data No other relevant technical data. APPENDIX BEVALUATION STATEMENTS B1 Evaluation methods 1.Spread of Fire Provisions A5.2(1)(e). A report from a professional engineer. B2 Reports The below reports outline the compliance of the DeltaTrim DualCore & DeltaOrb DualCore in relation to the Spread of fire Properties as required by H3P1(1) 1.SOTERA Pty Ltd; Fire Engineers Report No. A21007 J001 Rev 1-10; DeltaDualCore Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023. Provides Compliance with H3P1(1). 2.AWTA; NATA Accreditation No. 1356; Test No. 19-003619; Testing in accordance with AS/NZS 1530.3-1999; Dated 30/07/2019. Contributes towards Compliance withH3P1(1)3.CSIRO Certificate of Test: AS1530.3-1999 fire test certificate for Bluescope COLORBOND Metalic Steel Polyester, Report No. FNE11605; Dated 11/02/2016. Contributes towards Compliance withH3P1(1)4.CSIRO Certificate of Test: AS1530.3-1999 fire test certificate for UniCote pre-painted steel sheeting, Report No. FNE11809A; Dated 12/10/2016. Contributes towards Compliance withH3P1(1)5.CSIRO Certificate of Test: AS1530.1-1994 fire test certificate for Mineral Wool / Rockwool, Report No. FNC12604; Dated 08/07/2020. Contributes towards Compliance withH3P1(1)6.AWTA Product Testing: AS1530.3-1999 Test Report for DeltaTrim-EPS-FR, Test Number 19-003623; Dated 31/07/2019. Contributes towards Compliance withH3P1(1)The Certificate Holder has chosen not to make some of the above evidence of compliance publicly available, due to the documents being considered commercial in confidence. Certificate number: CM40330-I02-R00This certificate is only valid when reproduced in its entirety.Page 4 of 4'