b'DELTA PATIO & ROOFING RANGEDetail B Detail C Detail ADeltaTrimTrim TMAcoustic Values Early Fire Hazard Properties AS 1530-1999DeltaTrimTrim TM- EPS-FR Panel75mm 150mm Index Test External 100 15.41 15.00 Range Top Skin160 16.40 15.09 Ignitability 0-20 0200 18.81 17.70 Spread of Flame 0-10 0250 19.70 18.51 Heat Evolved 0-10 0315 21.39 19.40400 22.31 19.69 Smoke Developed 0-10 2630 23.40 19.10Frequency 800 23.69 17.31 DeltaTrimTrim TMFixing Details1000 25.61 18.29 Crest fixing only. One fixing every second crest1250 21.01 30.10 Panel ThicknessFixing into Steel Fixing into Timber1600 20.00 36.19 (mm)2000 34.79 37.30 Tek 14 x 200T17 14 x 200 2500 41.70 37.09 75 Hex Head Screw Hex Head Screw3150 44.10 35.69 100 Tek 14 x 230T17 14 x 230 5000 44.61 39.90 Hex Head Screw Hex Head ScrewSTC 24.00 23.00 125 Tek 14 x 230T17 14 x 230 RW 25.00 24.00 Hex Head Screw Hex Head Screw150 Tek 14 x 260T17 14 x 265 DeltaTrimTrim TM Acoustic Testing has been performedHex Head Screw Hex Head Screwin compliance with the requirements of AS 1191-2002Tek 14 x 300T17 14 x 300 Acoustics-MethodforLaboratoryMeasurementof175 Hex Head Screw Hex Head ScrewAirborne Sound Insulation of Building Elements.Tek 14 x 300T17 14 x 300 The procedures specified by AS 1276-1979 and AS/ 200 Hex Head Screw Hex Head ScrewNZS ISO 717.1:2004 were used to calculate the Sound TransmissionClass(STC)andtheWeightedSoundUse Cyclone Plate and Neo Washer on each fixingReduction Index (Rw) of DeltaTrimTrim TM . Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.DeltaTrimTrim TMis classed as trafficable when used in* Please refer to the web page for the available colour range, paint a roof application.finishes and relevant warranty conditions.P: +61 7 3271 2170E: info@deltapanels.comW: www.deltapanels.com A: 731 Boundary Road, Richlands, Qld 4077ABN: 11 147 861 292Delta Panels Pty Ltd 11'