b'Delta Panels Pty Ltd Delta Panels - Panel testing to FP1.4 and 4284 Test Report AS_NZS 42845Test Equipment Table 4: Test Equipment MeasurementInstrument/MakeModelAsset ID DistanceTape Measure8m000033666 PressureManometerPCEPDA-10L000033540 PressureManometerTECDG-700000033498 Water flow rateFlow MeterSiemensMAG6000000031229 Air Flow RateCalibrated fan - TECDuct Blaster000033497 TimeStopwatchY12990000335676Test Results 6.1Clause 8.2Preliminary tests Test Standard:AS/NZS 4284:2008Testing of Building Facades Test Date:02/06/2021 Criteria:Static Pressure - Test sample shall withstand the Serviceability Limit State pressure with no structural damage or distortion. Water tests - Under static and cyclic water tests there shall be no leaks. A leak is considered to occur when one or more of the following occur: a)Water appears on any inside surface of the faade, visible from an occupied space. b)Uncontrolled water appears on any inside surface of the faade (uncontrolled water is defined as any leakage not contained and drained away after 5 minutes). c)Water appears that is likely to wet insulation, fixtures and finishes. d)Water appears in other locations specified as unacceptable by the Specifier Applied Load:Static Pressure 1.63kPa, -2.45kPaDuration: 10s Static water test0.49 kPa Duration: water spray operated for 5 minutes at 0 kPa chamber pressure, followed by water spray and pressure at the test pressure for 15 minutes. Observe for 5 minutes after removal of both water and air pressure. Water spray: 3.0 L/min/m 2 37.5 L/min 30B-20-0134-TRP-16554-030 July 2021Page 6 of 11'