b'Delta Panels Pty Ltd Delta Panels - Panel testing to FP1.4 and 4284 Test Report AS_NZS 4284Cyclic water testTable 5: Cyclic water test pressure conditions StageLower pressureUpper pressureCycle Duration Stage 10.245 kPa0.490 kPa5 minutes 0 kPa2 minutes Stage 20.327 kPa0.654 kPa5 minutes 0 kPa2 minutes Stage 30.490 kPa0.980 kPa5 minutes Observation0 kPa5 minutes Water sprayFor the static and cyclic water tests the water was plied at the following rates during spray operation; 3.0 L/min/m 2applied over 12.48m 2= 37.4L/min. Results:The SLS pressure was achieved and maintained successfully, no water leaks were present during the static and cyclic water pressure tests. Conclusion:The sample complied with the requirements of Clause 8.2 of AS/NZS 4284:2008. 30B-20-0134-TRP-16554-030 July 2021Page 7 of 11'