b'Delta MW and EPS-FR Panel Awning and Patio Roof System Table 3-1. Manufacturers material specification (from Delta Panels Mineral WoolAwnings & Patio Brochure V20.10.21). Top skin0.42mm / G550 AZ150 Steel skin detail for Panel Type I Bottom skin0.55mm / G300 Z275 Steel skin detail for Panel TypeTop skin0.42mm / G550 AZ150 IIBottom skin0.60mm / G300 Z275 Panel Type I - Mineral wool Core materialPanel Type II - SL grade Polystyrene with fire retardant Panel Type I - Min. 0.042 W/mK @ 23.0CThermal conductivity Panel Type II - Min. 0.0363 W/mK @ 23.0C 75 mm Panel2.08 100 mm Panel2.78 Panel Type I R Value @22.5C 125 mm Panel3.48 150 mm Panel4.17 75 mm Panel2.50 100 mm Panel3.30 Panel Type II R Value @22.5C 125 mm Panel4.20 150 mm Panel5.00 Sheet coverage1000 mm Length (mm)Min. of 1800 mm (cut to length) Thickness (mm)75, 100, 125, 150 Table 3-2. DeltaOrb fixing details (crest fixing only, one fixing every second crest)(from Delta Panels Mineral WoolAwnings & Patio Brochure V20.10.21). Panel ThicknessFixing into steel 75Tek 14 x 135 Hex Head Screw 100Tek 14 x 150 Hex Head Screw 125Tek 14 x 175 Hex Head Screw 150Tek 14 x 200 Hex Head Screw *Use cyclone plate and neo washer on each fixing. Upon installation the overlap needs to be stitch screwed or riveted every 300mmRevision 1-414'