b'Delta MW and EPS-FR Panel Awning and Patio Roof SystemFigure 4-15. Combustible fascia permitted up to but not closer than 450 mm to an allotment boundary (NCC Figure 9.2.9a).4.9Conclusion and Compliance This fire engineering report confirms that the Delta MW and EPS-FR roof system which may comprise of; (r)1 x Panel Type I (at least 900 mm in width) positioned parallel to the site boundary (see Figure 3-4), (s)Any number of Panel Type II located more than 900 mm form the site boundary (see Figure 3-4), (t)A non-combustible support structure, (u)Non-combustible plumbing fixtures (gutters and downpipes), (v)A width of 1000 mm, (w)cut to length (1800 mm minimum), (x)Panel Type I and Panel Type II may range in thickness from 75 mm -150 mm, (y)Panel Type I can be of the DeltaOrb MW or DeltaTrim MW system profiles with top skin consisting of 0.42mm G550 AZ150 steel and bottom skin consisting of 0.55mm G300 Z275 steel, (z)Panel Type II can be of the DeltaOrb EPS-FR or DeltaTrim EPS-FR system profiles with top skin consisting of 0.42mm G550 AZ150 steel and bottom skin consisting of 0.60 mm G300 Z275 steel meet the performance requirements of H3P1(1) Volume 2, NCC 2022 when installed in accordance with the Delta Panels Mineral WoolAwnings & Patio Brochure V20.10.21 and Section 4.4 of this report as a Class 10a structure (awning or patio roof) attached or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e. less than 900 mm from the site boundary). The comparative assessment has demonstrated qualitatively and quantitatively that the Delta MW and EPS-FR system (when installed to the requirements of Section 4.4) does not increase the risk of fire spread from or to an associated Class 1 building when compared to the DtS base case.Performance requirement H3P1(1) is satisfied. The assessment is compliant in accordance with A2G2(1)(b) and A2G2(2)(d).Revision 1-435'