b'Delta MW and EPS-FR Panel Awning and Patio Roof System Smoke Developed: 3 Sandwich Panel with Expanded Polystyrene (EPS-FR) CoreTestReportTest SpecimenRelevant Performance 4.AS1530.3:1999AWTA Test No.Pre-painted steelIndices: 19-003621 (referskins (DeltaOrb) Ignitability: 0 to Section D.1)bonded to an EPS-FR core with fireSpread of Flame: 0 retardant. Heat Evolved: 0 Smoke Developed: 2 5.AS1530.3:1999AWTA Test No.Pre-painted steelIndices: 19-003623 (referskins (DeltaTrim) Ignitability: 0 to Section D.2)bonded to an EPS-FR core with fireSpread of Flame: 0 retardant.Heat Evolved: 0 Smoke Developed: 2 6.INTENTIONALLY LEFT BLANK Coated Steel Facings TestReport Test SpecimenRelevant Performance 7.AS1530.3:1999CSIRO ReportBlueScopeIndices: No. FNE11602ZINCALUME Steel Ignitability: 0 (refer to Section(0.42 mm nominal D.5)thickness)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 8.AS1530.3:1999AWTA Test No.MagnaFlow CoatedIndices: 19-002186 (referSteel Panel (nominal Ignitability: 0 to Section D.6)mass per unit density 7850 kg/m 3 )Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 3 9.AS1530.3:1999CSIRO ReportUniCote steel (0.55Indices: No. FNE11809Amm nominal Ignitability: 0 (refer to Sectionthickness) D.7)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 10.AS1530.3:1999AWTA Test No.UniZinc (low carbonIndices: 20-000776 (refersteel) Rigid Panel (< Ignitability: 0 to Section D.8)1 mm nominal thickness)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 0-1 Revision 1-416'