b'A3 Product specificationDeltaOrb MW Fixing DetailsDeltaOrb EPS-FR Fixing Details Crest fixing only. One fixing every second crestCrest fixing only. One fixing every second crest Panel ThicknessFixing into SteelPanel ThicknessFixing into Steel 75mmTek 14 x 135mm Hex Head Screw75mmTek 14 x 135mm Hex Head Screw 100mmTek 14 x 150mm Hex Head Screw100mmTek 14 x 150mm Hex Head Screw 125mmTek 14 x 175mm Hex Head Screw125mmTek 14 x 175mm Hex Head Screw 150mmTek 14 x 200mm Hex Head Screw150mmTek 14 x 200mm Hex Head ScrewDeltaTrim MW Fixing DetailsDeltaTrim EPS-FR Fixing Details Crest fixing only. One fixing every second crestCrest fixing only. One fixing every second crest Panel ThicknessFixing into SteelPanel ThicknessFixing into Steel 75mmTek 14 x 150mm Hex Head Screw75mmTek 14 x 150mm Hex Head Screw 100mmTek 14 x 175mm Hex Head Screw100mmTek 14 x 175mm Hex Head Screw 125mmTek 14 x 200mm Hex Head Screw125mmTek 14 x 200mm Hex Head Screw 150mmTek 14 x 230mm Hex Head Screw150mmTek 14 x 230mm Hex Head ScrewUse Cyclone Plate and Neo Washer on each fixing. Upon Installation the overlap needs to be stitch screwed or riveted every 300mm. Roof PitchDeltaTrim-MW and DeltaTrim EPS-FR 2 DeltaOrb-MW and DeltaOrb EPS-FR3Certificate number: CM40346-I02-R00This certificate is only valid when reproduced in its entirety.Page 4 of 6'