b'STEP 3SELECT THE STYLE OF ROOF SHEETINGStep 3.2 Insulated Spans -EPS-FR-TPCSINGLE-SPAN NON-CYCLONIC SPAN TABLESTYPE 1 TYPE 2 TYPE 3 TYPE 4 MaximumWind Panel OverhangCategory Thickness (3 or more sides(2 sides open) (1 side open) (Fully enclosed) (Each end)open)50mm 5400 5000 4500 4300 90075mm 6500 5500 5000 4700 900100mm 7200 6200 5700 5500 1000N1/N2 125mm 7800 6800 6400 6800 1200(W28 /W33)150mm 8200 7400 7000 6800 1200175mm 8600 8000 7500 7000 1200200mm 9000 8600 8000 7200 120050mm 4800 3800 3300 3000 90075mm 5500 4300 3900 3700 900100mm 6200 5000 4500 4300 1000N3 125mm 6800 5500 5000 5000 1200(W41)150mm 7400 6000 5500 5100 1200175mm 8000 7500 6000 5900 1200200mm 8600 8000 6500 6300 120050mm 4000 3300 3000 3000 60075mm 4600 3600 3400 3300 600100mm 5300 4100 3800 3500 800N4 125mm 6000 4500 4200 4000 900(W50)150mm 6600 5200 4800 4600 900175mm 7000 5800 5200 5000 900200mm 7400 6400 5600 5400 90050mm 3300 2800 2400 2200 60075mm 3600 3000 2800 2500 600100mm 3900 3300 3100 3000 600N5 125mm 4100 3800 3500 3300 600(W60)150mm 4500 4300 3900 3500 600175mm 5000 4700 4400 4200 600200mm 5500 5100 4800 4600 600ABN: 11 147 861 292E: info@deltapanels.com P: +61 7 3271 2170 W: www.deltapanels.com Version Date:22A: 731 Boundary Road, Richlands, Qld 4077Sydney Depot: 11 The Old Northern Road, Narellan, NSW 25672024-03-24'