b'DeltaFireX TMCar Port System bonded to an MWSpread of Flame: 0 core. Heat Evolved: 0 Smoke Developed: 3 Coated Steel Facings TestReport Test SpecimenRelevant Performance 4.AS1530.3:1999CSIRO ReportBlueScopeIndices: No. FNE11602ZINCALUME Steel Ignitability: 0 (refer to Section(0.42 mm nominal B.3)thickness)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 5.AS1530.3:1999AWTA Test No.MagnaFlow CoatedIndices: 19-002186 (referSteel Panel (nominal Ignitability: 0 to Section B.4)mass per unit density 7850 kg/m 3 )Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 3 6.AS1530.3:1999CSIRO ReportUniCote steel (0.55Indices: No. FNE11809Amm nominal Ignitability: 0 (refer to Sectionthickness) B.5)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 7.AS1530.3:1999AWTA Test No.UniZinc (low carbonIndices: 20-000776 (refersteel) Rigid Panel (< Ignitability: 0 to Section B.6)1 mm nominal thickness)Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 0-13.3.2Extrapolation of Fire Test Results All relevant fire testing referenced within this report are given in Table 3-4 with a summary of the fire performance achieved in each case.A number of coated steel and steel-alloy sheet metals have been tested to AS1530.3:1999 both independently and as part of a sandwich panel. When tested independently (tests 4 to 7 in Table 3-4), the test results obtained for each AS1530.3 index (Ignitability, Spread of Flame, Heat Evolved and Smoke Developed) are almost identical with only a small variance in the Smoke Developed Index. In all cases, the AS1530.3 results are within the following value range:Ignitability Index: 0 (Range 0-20) Spread of Flame Index: 0 (Range 0-10) Heat Evolved Index: 0 (Range 0-10) Smoke Developed Index: 0-3 (Range 0-10) Revision 1-415'