b'DeltaFireX TMCar Port System 2.3Scope of Project. The assessment relates to the final state of the building. This assessment and report does not address any issues of variation from deemed-to-satisfy requirements and occupant safety that may arise as a result of partial completion and partial occupation of the building. Analysis of intentional fire incidents such as arson is not contemplated as part of this assessment. This assessment will address the issues of variation from deemed-to-satisfy provisions of the BCA, which are identified in the summary of this report (Section 1).The assessment is concerned primarily with the life safety of occupants.The fire safety systems to achieve this are outlined in the report in principle.The assessment does not consider property protection, business continuity issues, environmental protection and insurance requirements unless specifically identified within this report.This assessment only addresses the specific issues identified in the context that the remainder of the building is fully compliant with the deemed-to-satisfy provisions of the NCC.2.4Supporting Information The fire engineering assessment described in this report is based on the following information: i)Branz Fire Assessment Report FC10893-001: Assessment of Delta Panels Pty Ltd DeltaCool wall and DeltaTrim and DeltaOrb roofing systems for compliance with BAL-29 and BAL-40 Ratings of AS3959-2009. ii)CSIRO Certificate of Test: AS1530.1-1994 fire test certificate for Mineral Wool / Rockwool, Report No. FNC12604. iii)CSIRO Certificate of Test: AS1530.1-1994 combustibility test for low carbon steel manufactured by Bluescope Australia No. FNC12440. iv)AWTA Product Testing: AS1530.3-1999 Test Report for DeltaOrb-MW, Test Number 21-003529. v)AWTA Product Testing: AS1530.3-1999 Test Report for DeltaTrim-MW, Test Number 21-003527. vi)CSIRO Certificate of Test: AS1530.3-1999 fire test certificate for Bluescope ZINCALUME Steel, Report No. FNE11602. vii)CSIROCertificateofTest:AS1530.3-1999firetestcertificateforUniCotepre-paintedsteel sheeting, Report No. FNE11809A. viii)AWTA Product Testing: AS1530.3-1999 Test Report for Uni Zinc Rigid Panel, Test Number 20-000776. ix)AWTA Product Testing: AS1530.3-1999 Test Report for MagnaFlow Coated Steel Panel, Test Number 19-002186. x)DeltaFireXRoof car port system brochure V15.10.21. xi)DeltaTrim-MW Specifications (from https://www.deltapanels.com.au/downloads-delta-panels accessed 19/10/2021). xii)DeltaOrb-MW Specifications (from https://www.deltapanels.com.au/downloads-delta-panels accessed 19/10/2021). xiii)Architectural drawings referenced in Table 2-1.Table 2-1. List of drawings relied upon. Drawn by:Delta Panels Pty Ltd Drawing NoTitleRevision PATIO ON BOUNDARY MW_1-A Revision 1-47'