b'Fire Engineering Assessment, Revision 01 DeltaCool, DeltaSecrectFix, DeltaTrim at 100 mm and 75 mm Fire Performance, Project No. 25367 25367-SFE-FEA-01-Delta Panel Fire Performance 1FIRE ENGINEERING ASSESSMENT ITEMS Table 1-1 summarises the assessed NCC DtS departures, associated NCC DtS Clauses, Fire Engineering Assessment, Performance Requirements and relevant Assessment Section. Table 1-1Fire Engineering Assessment Items ItemSection of ReportNCC DtS ClausePerformanceDescription of Departure Requirements 14.1C2D11, S7C4C1P2, C1P4,It is proposed to utilise the reaction to fire test report (RTF252619 C1P9R1.0) for the DeltaCool 100 mm thick panel to indicate the fire performance of the following panels: -DeltaCool 75 mm thick panel with a mineral wool core -DeltaSecretFix 100 mm thick panel with a mineral wool core -DeltaSecretFix 75 mm thick panel with a mineral wool core -DeltaTrim 100 mm thick panel with a mineral wool core -DeltaTrim 75 mm thick panel with a mineral wool corePage 5'